← Back to products
Enlarge image ↗
Enlarge image ↗
Enlarge image ↗
Enlarge image ↗
Enlarge image ↗Pump sectional illustration
Chemical Centrifugal Pumps / IHQ
EPF Chemical Centrifugal Pump
Product Description
A single-stage, single-suction chemical centrifugal pump for corrosive liquids and acid solutions. The pump casing and impeller are moulded from EPF medium-alkali glass-fiber reinforced material.
Technical Specifications
| Available speeds | 2950 / 1450 r/min |
|---|---|
| Models by speed | 21 models at 2950 r/min; 33 models at 1450 r/min |
| Flow range | 3–360 m³/h |
| Head range | ≤84 m |
| Construction | Single-stage, single-suction chemical centrifugal pump |
| Working pressure | 1.6 MPa class |
| Medium temperature | ≤110°C (general operating parameters) |
| Ambient temperature | ≤40°C |
| Solids content | ≤5% |
| Particle diameter | ≤0.5 mm |
| Hydraulic & interface standards | ISO 2858, DIN 24256 and GB 5662 |
Main Materials
| Pump casing | EPF medium-alkali glass-fiber reinforced moulding compound |
|---|---|
| Impeller | EPF medium-alkali glass-fiber reinforced moulding compound |
| Left / right clamping plates | HT200 |
| Shaft | 45 steel (quenched and tempered) or heat-treated martensitic stainless steel |
| Base | Grey cast iron |
| Mechanical seal | S-SiC / SiC (imported material) |
| Bearings | SKF bearings with dust seals; no grease addition required |
Model Specifications
Each model below includes all three flow/head duty points stated in the catalog. Motor power, NPSHr and inlet/outlet diameters apply to that model and speed.
2950 r/min
21 models| Model | Duty point 1 | Duty point 2 | Duty point 3 | Motor power (kW) | NPSHr (m) | Suction Ø (mm) | Discharge Ø (mm) | |||
|---|---|---|---|---|---|---|---|---|---|---|
| Q (m³/h) | H (m) | Q (m³/h) | H (m) | Q (m³/h) | H (m) | |||||
| IHQ32-25-160A | 6 | 24.5 | 10 | 24 | 11.8 | 23.7 | 4 | 2 | 32 | 25 |
| IHQ32-25-160 | 6.9 | 32 | 11.5 | 31.5 | 13.5 | 31 | 4 | 2 | 32 | 25 |
| IHQ50-32-160 | 18 | 31 | 30 | 25 | 36 | 20 | 7.5 | 2 | 50 | 32 |
| IHQ50-32-200B | 18 | 36 | 30 | 31 | 36 | 26 | 7.5 | 2 | 50 | 32 |
| IHQ50-32-200A | 18 | 46 | 30 | 41 | 36 | 36 | 11 | 2 | 50 | 32 |
| IHQ50-32-200 | 18 | 54 | 30 | 46 | 36 | 42 | 15 | 2 | 50 | 32 |
| IHQ50-32-250A | 6.5 | 65 | 12.5 | 64 | 15 | 63.5 | 15 | 2 | 50 | 32 |
| IHQ50-32-250 | 6.5 | 84 | 12.5 | 83 | 15 | 82 | 18.5 | 2 | 50 | 32 |
| IHQ65-40-160A | 18 | 18 | 30 | 15 | 36 | 12 | 11 | 2 | 65 | 40 |
| IHQ65-40-160 | 18 | 30 | 30 | 26 | 36 | 24 | 11 | 2 | 65 | 40 |
| IHQ65-40-200A | 18 | 40 | 30 | 37 | 36 | 35 | 15 | 2 | 65 | 40 |
| IHQ65-40-200 | 18 | 51 | 30 | 50 | 36 | 49 | 15 | 2 | 65 | 40 |
| IHQ80-50-160A | 27 | 28.8 | 45 | 25 | 54 | 23.2 | 11 | 2.4 | 80 | 50 |
| IHQ80-50-160 | 30 | 36 | 50 | 32 | 60 | 29 | 11 | 2.4 | 80 | 50 |
| IHQ80-50-200A | 27 | 42.4 | 45 | 40 | 54 | 37.6 | 15 | 2.4 | 80 | 50 |
| IHQ80-50-200 | 30 | 53 | 50 | 50 | 60 | 47 | 18.5 | 2.4 | 80 | 50 |
| IHQ100-65-160A | 54 | 28.8 | 90 | 25 | 108 | 22.4 | 18.5 | 3.2 | 100 | 65 |
| IHQ100-65-160 | 60 | 36 | 100 | 32 | 120 | 28 | 22 | 3.2 | 100 | 65 |
| IHQ100-65-200A | 54 | 43.2 | 90 | 40 | 108 | 37.6 | 30 | 3.2 | 100 | 65 |
| IHQ100-65-200 | 60 | 54 | 100 | 50 | 120 | 47 | 37 | 3.2 | 100 | 65 |
| IHQ100-65-250A | 54 | 69.6 | 90 | 64 | 108 | 59.6 | 45 | 3.2 | 100 | 65 |
1450 r/min
33 models| Model | Duty point 1 | Duty point 2 | Duty point 3 | Motor power (kW) | NPSHr (m) | Suction Ø (mm) | Discharge Ø (mm) | |||
|---|---|---|---|---|---|---|---|---|---|---|
| Q (m³/h) | H (m) | Q (m³/h) | H (m) | Q (m³/h) | H (m) | |||||
| IHQ32-25-160A | 3 | 6.1 | 5 | 6 | 5.9 | 5.9 | 0.55 | 2 | 32 | 25 |
| IHQ32-25-160 | 3.5 | 8 | 5.8 | 7.8 | 6.8 | 7.7 | 1.1 | 2 | 32 | 25 |
| IHQ50-32-160 | 9 | 7.8 | 15 | 6.3 | 18 | 5 | 1.1 | 2 | 50 | 32 |
| IHQ50-32-200B | 9 | 9 | 15 | 7.8 | 18 | 6.5 | 1.5 | 2 | 50 | 32 |
| IHQ50-32-200A | 9 | 11.5 | 15 | 10.3 | 18 | 9 | 1.5 | 2 | 50 | 32 |
| IHQ50-32-200 | 9 | 13.5 | 15 | 11.5 | 18 | 10.5 | 2.2 | 2 | 50 | 32 |
| IHQ50-32-250A | 3.3 | 16.3 | 6.3 | 16 | 7.5 | 15.9 | 1.5 | 2 | 50 | 32 |
| IHQ50-32-250 | 3.3 | 21 | 6.3 | 20.8 | 7.5 | 20.5 | 1.5 | 2 | 50 | 32 |
| IHQ65-40-160A | 9 | 4.5 | 15 | 3.8 | 18 | 3 | 1.1 | 2 | 65 | 40 |
| IHQ65-40-160 | 9 | 7.5 | 15 | 6.5 | 18 | 6 | 1.1 | 2 | 65 | 40 |
| IHQ65-40-200A | 9 | 10 | 15 | 9.3 | 18 | 8.8 | 1.5 | 2 | 65 | 40 |
| IHQ65-40-200 | 9 | 12.8 | 15 | 12.5 | 18 | 12.3 | 2.2 | 2 | 65 | 40 |
| IHQ80-50-160A | 13.5 | 7.2 | 22.5 | 6.3 | 27 | 5.8 | 1.5 | 2.4 | 80 | 50 |
| IHQ80-50-160 | 15 | 9 | 25 | 8 | 30 | 7.3 | 2.2 | 2.4 | 80 | 50 |
| IHQ80-50-200A | 13.5 | 10.6 | 22.5 | 10 | 27 | 9.4 | 3 | 2.4 | 80 | 50 |
| IHQ80-50-200 | 15 | 13.3 | 25 | 12.5 | 30 | 11.8 | 4 | 2.4 | 80 | 50 |
| IHQ80-50-315A | 13 | 30 | 20 | 30 | 24 | 29.5 | 11 | 2.4 | 80 | 50 |
| IHQ80-50-315 | 15 | 45.5 | 25 | 45.5 | 30 | 45 | 15 | 2.4 | 80 | 50 |
| IHQ100-65-160A | 27 | 7.2 | 45 | 6.3 | 54 | 5.6 | 3 | 3.2 | 100 | 65 |
| IHQ100-65-160 | 30 | 9 | 50 | 8 | 60 | 7 | 4 | 3.2 | 100 | 65 |
| IHQ100-65-200A | 27 | 10.8 | 45 | 10 | 54 | 9.4 | 5.5 | 3.2 | 100 | 65 |
| IHQ100-65-200 | 30 | 13.5 | 50 | 12.5 | 60 | 11.8 | 7.5 | 3.2 | 100 | 65 |
| IHQ100-65-250A | 27 | 17.4 | 45 | 16 | 54 | 14.9 | 11 | 3.2 | 100 | 65 |
| IHQ100-65-250 | 30 | 20 | 50 | 18 | 60 | 17 | 11 | 3 | 100 | 65 |
| IHQ125-80-200A | 54 | 12.4 | 90 | 10.1 | 108 | 8.3 | 7.5 | 3 | 125 | 80 |
| IHQ125-80-200 | 60 | 15.3 | 100 | 12.5 | 120 | 10.3 | 11 | 3 | 125 | 80 |
| IHQ125-80-250A | 54 | 20.5 | 90 | 16.2 | 108 | 14.8 | 15 | 3 | 125 | 80 |
| IHQ125-80-250 | 60 | 22.5 | 100 | 20 | 120 | 18.3 | 18.5 | 3 | 125 | 80 |
| IHQ125-100-315A | 40 | 21.8 | 67.5 | 20 | 80 | 18.8 | 22 | 3 | 125 | 100 |
| IHQ125-100-315 | 60 | 33.3 | 100 | 31.3 | 120 | 30 | 30 | 3 | 125 | 100 |
| IHQ125-100-355 | 60 | 48 | 120 | 44 | 150 | 40 | 37 | 3 | 125 | 100 |
| IHQ150-125-315A | 144 | 21.8 | 240 | 18 | 288 | 16.7 | 55 | 3 | 150 | 125 |
| IHQ150-125-315 | 180 | 34 | 300 | 28.5 | 360 | 26 | 75 | 3 | 150 | 125 |
Applications
Transfer of corrosive liquids, including acid solutions.
Each model is listed with three flow/head duty points. The medium compatibility chart gives liquid-specific temperature limits that may differ from the general operating temperature. Select conditions for the actual medium.
Motor power in the installation drawings can differ from the performance data. Confirm the motor and installation dimensions for the medium density and actual duty point.
Technical Drawings & Dimensional Tables
EPF pump sectional drawingExpand technical sheet
Enlarge image ↗EPF main component materialsExpand technical sheet
Enlarge image ↗Outline & installation drawingExpand technical sheet
Enlarge image ↗Pump drawings retain their original Chinese labels.